Tensile System

Tensile Structures®

High-Performance Tensile Canopies

Architecturally striking PVDF-coated tensile structures engineered for Indian climate — monsoon-rated, wind-certified, and maintenance-free.

Request a Quote
ABOUT TENSILE STRUCTURES

What Are Tensile Structures?

Skyshade architectural tensile membrane structure

Tensile structures are engineered architectural systems in which flexible membranes carry loads primarily through tension. Their surfaces are supported by designed steel elements, cables where required, and connection systems that stabilise the intended geometry.

Skyshade develops each solution around the proposed span, site conditions and architectural brief, coordinating membrane selection, supporting structures, fabrication and execution for the specific project.

Entrances & Walkways

Commercial Entrances & Campuses

Public Spaces

Plazas, Pavilions & Events

Transport & Sports

Transit Sites & Sports Venues

HOW DO TENSILE STRUCTURES WORK?

How Tensioned Membranes Work

A membrane gains its structural form through controlled pretension, while supports and connections transfer applied forces into the engineered supporting structure.

Phase 01 of 05
STEP 01
Phase 01

Supporting Structure

Steel members establish the structural geometry and receive forces transferred from the tensioned membrane assembly.

Next: Phase 02
STEP 02
Phase 02

Membrane Surface

Architectural fabric forms the load-carrying surface, working primarily in tension rather than bending under loads.

Next: Phase 03
STEP 03
Phase 03

Edge Connections

Edge details connect the membrane to supporting components and distribute forces along its boundaries appropriately.

Next: Phase 04
STEP 04
Phase 04

Tensioning System

Specified pretension keeps the membrane shaped and enables its response to changing environmental actions safely.

Next: Phase 05
Result
Phase 05

Structural Load Transfer

Membrane forces pass through edges and connections into engineered supports and the foundations below them.

Final Outcome

The complete system depends on coordinated geometry, material behaviour, supporting members and project-specific structural engineering.

KEY FEATURES

Engineered for Architectural Freedom

These systems combine expressive architectural form with practical coverage, offering options for shaded, sheltered and visually open spaces where appropriately designed.

Material selection, geometry and site conditions determine which benefits an individual installation can effectively deliver.

Tensile Structures - Lightweight Coverage
Tensile Structures
01 / 06
✦ Advantage 01: Lightweight Coverage
Key Advantages (6) Tap card or arrows above
01
Lightweight

Lightweight Coverage

Lightweight membranes provide extensive overhead coverage without requiring an extensive continuous rigid roofing surface beneath.

02
Sculptural Forms

Architectural Design Freedom

Sweeping curves and sculptural profiles help architects create distinctive landmarks tailored to individual project settings.

03
Shade

Effective Solar Shading

Purpose-designed canopies create shaded areas for outdoor movement, waiting and gathering under strong daytime sunlight.

04
Shelter

Rain Protection

Suitable membranes and correctly detailed drainage can provide shelter from rainfall in covered areas outdoors.

05
Diffuse Light

Natural Daylight Access

Translucent membranes can admit diffuse natural light beneath the canopy while limiting direct sunlight exposure.

06
Open Airflow

Open Space Comfort

Open-sided configurations retain airflow and visual connections to surrounding areas while covering occupied spaces overhead.

Custom Form, span and geometry
PVC Coated polyester membranes
Steel Engineered support structure
Tested to international daylight & architectural standards
WHERE CAN TENSILE STRUCTURES BE USED?

Designed for Diverse Spaces

From transport facilities to campuses and hospitality venues, custom membrane covers can respond to different circulation, gathering and shelter requirements.

Each use requires an appropriate assessment of access, exposure, span, support conditions and the intended activities.

01/01
Commercial Entrances
01
Entrances

Commercial Entrances

Entrance canopies create sheltered arrival areas at commercial buildings while expressing a recognisable architectural identity.

Walkways & Campuses
02
Walkways

Walkways & Campuses

Covered circulation routes can protect pedestrians moving between campus blocks, plazas and adjacent buildings outdoors.

Sports & Recreation
03
Sports

Sports & Recreation

Membrane roofs can shade spectator seating and selected activity areas while accommodating sports venue geometries.

Hospitality & Resorts
04
Hospitality

Hospitality & Resorts

Custom structures can shelter dining terraces, resort gathering areas and seasonal hospitality functions from sunlight.

Transportation Infrastructure
05
Transport

Transportation Infrastructure

Passenger waiting and drop-off areas can receive tailored overhead shelter at transport infrastructure sites outdoors.

Public & Event Spaces
06
Public Spaces

Public & Event Spaces

Exhibition pavilions and civic plazas can incorporate expressive covers for public gatherings and programmed events.

Have a Complex or Custom Architectural Layout?

Our daylighting engineers run comprehensive 3D Dialux & Radiance photometric simulations to calculate delivered lux for your exact floor drawings.

Request a Feasibility Study
Technical Specifications

Materials & Technical Specifications

Technical system selection considers membrane properties, structural geometry, environmental actions and connection design; final values must follow approved project documentation.

Tensile Structures — view 1

Product

Tensile Structures®

01

Fabric Type

PVDF-coated high-tensile polyester

1 of 8
02

Wind Load Resistance

150 km/h (IS 875 Part 3)

2 of 8
03

Fabric Weight

900–1500 g/m²

3 of 8
04

Frame Material

Hot-dip galvanised steel / SS 316

4 of 8
05

Span Range

Up to 40m column-free span

5 of 8
06

Fire Rating

B1 self-extinguishing (EN 13501-1)

6 of 8
07

Colour Options

500+ RAL / custom printed

7 of 8
08

Fabric Warranty

20 years

8 of 8

* Specs may vary by model. Hover to pause auto-advance.

Note: Final material specifications, structural calculations, membrane properties and installation requirements are determined during project engineering and material selection.

WHY CHOOSE SKYSHADE?

Why Choose
Skyshade?

Skyshade combines customised architectural design with engineering, production infrastructure and coordinated on-site execution to develop solutions around each project’s requirements.

This coordinated delivery model helps align architectural intent, technical decisions, fabrication and execution throughout the project.

Skyshade architectural tensile membrane canopy structure

Custom Architectural Design

Design teams adapt canopy form and layout to the intended site, span and architectural brief.

Structural Engineering Expertise

Engineering teams evaluate geometry, loading conditions and supporting arrangements to develop an appropriate structural solution.

In-House Manufacturing

In-house production capabilities support coordination of structural components, connection hardware and approved fabrication requirements effectively.

Site Execution Expertise

Installation teams coordinate site assembly with the architectural and engineering requirements established for each project.

20+Years of Expertise
2003Since Inception
CustomStructures Built
HOW WE WORK

From Architectural Vision to Installation

Skyshade follows an integrated approach to design and deliver tensile membrane structures that align with architectural, structural, and site requirements.

5-Step Process
01/05
Skyshade tensile architectural canopy membrane structure
Skyshade Certified Process
✦ Step 01:Requirement Assessment
STEP 01

Requirement Assessment

Understand architectural intent, intended use, proposed span, and site requirements.

Next: Site Evaluation→
STEP 02

Site Evaluation

Assess site conditions, structural interfaces, access arrangements, and ground or building support conditions.

Next: System Design & Engineering→
STEP 03

System Design & Engineering

Develop membrane geometry, steel support structure, connection details, and drainage in line with project engineering.

Next: Manufacturing & Installation→
STEP 04

Manufacturing & Installation

Fabricate the membrane and steelwork, then erect and tension the structure according to approved drawings.

Next: Inspection & Handover→
✦ FINAL

Inspection & Handover

Inspect membrane geometry, connections, and drainage before final acceptance and handover.

Quality Certified→
INSTALLATION GUIDE

Installation OverviewInstallation is a specialist supervised construction activity guided by approved engineering documentation, site conditions and the project's required safety controls.

01. Site Verification

Site teams confirm approved structural interfaces, access arrangements and relevant ground or building support conditions.

Tensile Structures — 03. Connection Preparation
Tensile Structures — 04. Membrane Positioning
Tensile Structures — 02. Steel Structure Erection
Tensile Structures — 05. Tensioning & Inspection
Tensile Structures — 01. Site Verification
Tensile Structures

01. Site Verification

Site teams confirm approved structural interfaces, access arrangements and relevant ground or building support conditions.

The sequence is indicative only; the contractor must follow approved method statements and engineering supervision.

Start Your Project · Tensile Structures

Bring Your Architectural Vision to Life

Discuss your site, proposed span, intended use and architectural requirements with Skyshade to explore a tailored membrane structure and the next steps for technical assessment.

Free Site Assessment
10-Year Warranty
Pan-India Delivery
Post-install Audit